![]() If salt is needed start with one bag to see if that helps which should add 300-400 ppm to the ASR after 48 hours. You may need additional salt but before adding the salt you should probably verify the salt level with a pool store or with a digital tester. If the ASR falls to 2400 ppm or below the Check Salt Light will be SOLID. If the ASR falls below 2700 ppm the Check Salt light will start BLINKING. However, it doesn’t ALWAYS go off so if the AquaRite panel still says it’s generating consider yourself fortunate. The unit will still produce chlorine until the reading goes above 4000 ppm and the GENERATING light usually will go off. However, the reading can go up to 4000 ppm before the Hi Salt light appears. 2700-3400 ppm is the idea recommended levels. This is a 24 hour average reading of salt measurement during ON cycles. Please click on the item that you are interested in. We go into more detail about what each of these numbers mean and what happens when they are higher or lower than the range. If T-cell setting DOES NOT appear on display it means that the board software revision is r.140 or lower. Instant salt reading (displays as a negative number).Cell amperage (4 -8a range when on, 0a when off).Average salt reading (2700 ppm -3400 pm is ideal).What do the numbers on my digital display mean? ![]()
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |